by Elorum

EMG, compared against healthy reference cohorts.

Research use only. Not for diagnostic use.

Every measurement, placed against healthy adults

Parmotus checks every recording, measures more than 200 features of how each muscle behaves, and shows where each measurement sits relative to healthy adults recorded doing the same task. Every processing step is written into the report, so every result can be audited.

Research use only. Not for diagnostic use.
Recording
S07_walk_overground.c3d
Task
Walking, overground
Reference
Walking, 7 muscles, 5 labs, 52 to 268 healthy adults
Signal quality
Good
Healthy range, 2.5th to 97.5th percentile 50th percentile This recording Percentile
Tibialis anterior : 32 measurements, 2 outside the reference range
Onset timing, dominant
timing · 58.2 % cycle
Percentile 71
Onset timing, dominant against non-dominant
asymmetry · 2.4 % cycle
Percentile 90
2 of 32 shown in this example
Gastrocnemius : 32 measurements, 2 outside the reference range
Peak timing, dominant
timing · 51.0 % cycle
Percentile 98
Outside healthy range
1 of 32 shown in this example
Rectus femoris : 32 measurements, 1 outside the reference range
Stride-to-stride variability, non-dominant
variability · 18.4 %
Percentile 55
1 of 32 shown in this example
Erector spinae : 37 measurements, 2 outside the reference range
Second burst timing, dominant
timing · 49.6 % cycle
Percentile 23
1 of 37 shown in this example
Semitendinosus : 32 measurements, 20 missing
Median frequency, non-dominant
frequency · no value
Missing: channel excluded, no signal
1 of 32 shown in this example
Co-contraction : 6 measurements, 1 missing
Rectus femoris and biceps femoris, dominant
co-contraction · 0.31
Percentile 84
Tibialis anterior and gastrocnemius, non-dominant
co-contraction · 0.18
Percentile 37
2 of 6 shown in this example
Vastus lateralis : 32 measurements, 1 outside the reference range
Onset timing, non-dominant
timing · 91.7 % cycle
Percentile 46
1 of 32 shown in this example
Biceps femoris : 32 measurements, 2 outside the reference range
Peak timing, dominant
timing · 94.1 % cycle
Percentile 62
1 of 32 shown in this example

Outside the healthy range means this recording differs from the cohort. Electrode placement and equipment are possible causes, not only physiology.

No score is produced for this recording.
Parmotus compares each measurement with healthy references.
Processing record and data credits
Processing record: prior band-pass filtering declared by user (20 to 450 Hz). 2 channel labels supplied by user, not read from file. 1 channel excluded: no signal. Comparisons for amplitude features: within-lab only.
Reference cohort derived from Van Criekinge et al. 2023 (doi:10.6084/m9.figshare.c.6503791.v1), CC0 1.0; Boo et al. 2025 (Gait120) (doi:10.6084/m9.figshare.27677016.v1), CC BY 4.0; Lencioni et al. 2019 (doi:10.6084/m9.figshare.c.4494755.v1), CC0 1.0 at the repository; Schreiber & Moissenet 2019 (doi:10.6084/m9.figshare.7734767.v8), CC BY 4.0; Di Nardo et al. 2024 (doi:10.13026/grdj-qx06), Open Data Commons Attribution License 1.0. Aggregated and re-analysed.
Illustrative report, Detail view. Values are examples, not participant data.

EMG is hard to trust and hard to compare. Parmotus is built around that.

Every lab records differently.

Amplifiers, electrodes, sampling rates, filters, and file formats vary, so a number from one lab often means something else in another. Parmotus reads common formats against a published data contract and tells you which measurements compare across labs.

Signal quality is judged by eye.

Parmotus excludes dead channels and reports their measurements as missing, and raises warnings for clipping, mains hum, and drift. The report says which channels were excluded and why.

Few labs have a healthy baseline.

Parmotus ships healthy reference cohorts for walking, reaching, and grasping, built from public research datasets and tested for calibration.

Pipelines change data without saying so.

Every filter, correction, and user-supplied label is recorded and printed in the report, so a result can be reproduced.

Six steps, every one on the record

  1. Upload

    C3D, CSV, NumPy, ZIP bundles, and several research-dataset formats.

  2. Validate

    Each error names the field, the problem, what was expected, and how to fix it.

  3. Check quality

    Dead channels are excluded and their measurements reported missing. Clipping, mains hum, and drift raise warnings.

  4. Measure

    Over 200 features per walking recording, each labelled with its side.

  5. Compare

    Each measurement placed against the matching healthy cohort as a percentile. No matching cohort, no comparison.

  6. Report

    A PDF and a machine-readable result file, both carrying the full processing record and data credits.

Healthy reference cohorts, tested before they ship

Each cohort matches a task, a set of muscles, an electrode type and, for walking, a speed range. When a recording matches none of them, Parmotus withholds the comparison and explains why. Summary shows only comparisons that held up in two or more labs; single-lab references appear in Detail.

Task Muscles and electrodes Healthy adults Labs
Walking, overground (0.79 to 2.10 m/s) Summary and Detail 15 leg and trunk muscles, surface EMG 336 5
Walking, treadmill (0.8 to 2.1 m/s) Summary and Detail 16 leg and trunk muscles, surface EMG 182 3
Walking, overground, slow (0.47 to 0.79 m/s) Detail only 8 leg muscles, surface EMG 50 1
Stair ascent, stair descent Detail only 11 leg and trunk muscles, surface EMG 22 each 1
Ramp ascent, ramp descent Detail only 11 leg and trunk muscles, surface EMG 22 each 1
Reaching, three targets Detail only 11 arm and shoulder muscles, surface EMG 36 each 1
Finger-to-nose reaching Detail only 10 arm and shoulder muscles, surface EMG 20 1
Pinch grip, cylinder grip, non-dominant arm Detail only Forearm, high-density grid 23 each 1
Thumb-index pinch, hand close, dominant arm Detail only Forearm, two high-density grids 20 each 1
6.7%
median outside rate, walking reference

A healthy range should flag only the expected share of healthy people it has never seen. Tested by leaving one person out at a time, the walking reference flags 6.7% on the median measurement, against 6.8% for a perfectly calibrated range.

Outside rate for each of 355 walking measurements, healthy adults left out of the reference one at a time.

Tested on five labs, each left out in turn

Timing held up for 28 of 33 muscles tested, frequency 23, variability 21, amplitude 13. Summary shows only measurements that held up in at least two labs.

Measurement family Lab ALab BLab CLab DLab E
Timing 5 of 5 muscles held up 8 of 9 muscles held up 5 of 8 muscles held up 6 of 7 muscles held up 4 of 4 muscles held up
Variability 4 of 5 muscles held up 6 of 9 muscles held up 1 of 8 muscles held up 7 of 7 muscles held up 3 of 4 muscles held up
Frequency 2 of 5 muscles held up 9 of 9 muscles held up 3 of 8 muscles held up 7 of 7 muscles held up 2 of 4 muscles held up
Amplitude 0 of 5 muscles held up 5 of 9 muscles held up 5 of 8 muscles held up 3 of 7 muscles held up 0 of 4 muscles held up

Muscles that held up, of muscles tested.

Amplitude depends on amplifier gain, so Parmotus labels amplitude comparisons within-lab only.

Rules the software will not break

4% apart 98% 2% one stride not 94% apart

Timing measured on a circle

A stride has no edge. A muscle peaking at 2% of the stride and one peaking at 98% are 4% apart, not 94%. Parmotus compares timing on a circle, and treats muscles with two bursts per stride, like the erector spinae, as two bursts.

Dead is not the same as quiet

A channel with no signal would look like a muscle doing nothing, so Parmotus excludes it and reports its measurements missing. A quiet but live electrode is kept. The line between the two was measured on more than 23,000 channels, not assumed.

Missing is missing, never zero

A measurement that could not be computed is reported as missing, with the reason. A zero in its place would be averaged in as a real value.

Withheld is not an error

If the task, muscles, electrode type, or walking speed do not match a cohort, Parmotus says so and why instead of producing a confident wrong number.

Nothing is silently changed

Every transformation of the signal is recorded and shown.

Reproducible

The same input and software version give the same output, byte for byte, apart from the report’s timestamp.

Limitations written down

Every known limitation is written down: what does not transfer between labs, where event detection struggles, what a cohort can and cannot represent.

Built for how labs work

Runs locally

Analysis makes no network calls. Recordings leave the machine only if your lab chooses to share them with us under a data-sharing agreement.

Scriptable

Every capability in the app is also available from the command line, for processing recordings in bulk.

Corrections on the record

If a file does not say which muscle a channel is, you say so. The report records it as supplied, not read.

Help that stays offline

A small assistant built for the app answers “where is” and “how do I” questions and points to the control in the app. It replies only with pre-written answers, so it never makes claims about the science.

Where it is going

  1. Now: version 0.3

    Walking, stair, ramp, reaching, and grasping references, in Summary and Detail views. Validation, quality checks, more than 200 features, lab cohorts, comparison between sessions, PDF and machine-readable reports, a command-line tool, a guided tutorial, and licence activation checked offline.

  2. Next

    Motor-unit decomposition for high-density EMG, with motor-unit editing in the app. Standard EMG analyses run from the interface, with no code to write. Reference cohorts for needle and intramuscular EMG.

  3. With partner labs

    Reference cohorts for more populations, built with partner labs.

Built on published research data

Every reference cohort is built from published research datasets. Each one is credited in the app and in every report.

Free for partner labs.

For neuromuscular and rehabilitation research labs that record EMG. Tell us about your lab, the muscles you record, and your study. Each request is reviewed by hand, and approved labs receive a download for macOS, Windows, or Linux with a personal access key.

Request access