From recording to report, every step on the record
Parmotus checks an EMG recording, measures how each muscle behaves, and places each measurement against healthy adults recorded doing the same task. Version 0.3 covers walking (overground, treadmill, stairs, and ramps), reaching, and grasping.
What happens to a recording
1. Upload
One or more recordings of the same person: C3D, CSV, NumPy, ZIP bundles, and several research-dataset formats.
2. Validate
Each file is checked against a published data contract. Every error names the field, the problem, what was expected, and how to fix it.
3. Check quality
A channel with no signal, such as a dead or detached electrode, is excluded and its measurements are reported missing. Clipping, mains hum, and baseline drift raise warnings and never exclude a channel. The result is summarised as Good, Caution, or Poor.
4. Measure
More than 200 features per walking recording, each labelled with its side: dominant or non-dominant for healthy participants, affected or unaffected for participants with one affected side.
5. Compare
Each measurement is placed against the matching healthy reference cohort as a percentile, with the healthy range running from the 2.5th to the 97.5th percentile. Percentiles are age-adjusted for the walking, stair, ramp, and three-target reaching references. If no cohort matches the task, the muscles, the electrode type, or the walking speed, the comparison is withheld with an explanation.
6. Report
A PDF and a machine-readable result file. Both carry the full processing record and the data credits.
What is measured
Measurements are grouped into families:
- Amplitude: how strongly each muscle is active.
- Timing: when muscles switch on and off within a stride.
- Frequency: the frequency content of the signal.
- Variability: how consistent a muscle is from stride to stride.
- Co-contraction: opposing muscles active together. In walking, three pairs: rectus femoris and biceps femoris, vastus lateralis and semitendinosus, tibialis anterior and gastrocnemius.
- Coordination: how muscles work together across the task.
- Asymmetry: always of a named measurement, such as onset timing on one side against the other.
- Spatial: for high-density grids, where on the grid activity concentrates.
Results read “outside the healthy range” when a measurement falls beyond the 2.5th or 97.5th percentile. That means the recording differs from the cohort. Electrode placement and equipment are possible causes, not only physiology. No score is produced.
Healthy reference cohorts
Each cohort matches a task, a set of muscles, an electrode type and, for walking, a speed range. When a recording matches none of them, Parmotus withholds the comparison and explains why. Summary shows only comparisons that held up in two or more labs; single-lab references appear in Detail.
| Task | Muscles and electrodes | Healthy adults | Labs |
|---|---|---|---|
| Walking, overground (0.79 to 2.10 m/s) Summary and Detail | 15 leg and trunk muscles, surface EMG | 336 | 5 |
| Walking, treadmill (0.8 to 2.1 m/s) Summary and Detail | 16 leg and trunk muscles, surface EMG | 182 | 3 |
| Walking, overground, slow (0.47 to 0.79 m/s) Detail only | 8 leg muscles, surface EMG | 50 | 1 |
| Stair ascent, stair descent Detail only | 11 leg and trunk muscles, surface EMG | 22 each | 1 |
| Ramp ascent, ramp descent Detail only | 11 leg and trunk muscles, surface EMG | 22 each | 1 |
| Reaching, three targets Detail only | 11 arm and shoulder muscles, surface EMG | 36 each | 1 |
| Finger-to-nose reaching Detail only | 10 arm and shoulder muscles, surface EMG | 20 | 1 |
| Pinch grip, cylinder grip, non-dominant arm Detail only | Forearm, high-density grid | 23 each | 1 |
| Thumb-index pinch, hand close, dominant arm Detail only | Forearm, two high-density grids | 20 each | 1 |
Built from published research data: overground walking from Van Criekinge et al. 2023, Gait120, Lencioni et al. 2019, Schreiber & Moissenet 2019 and Di Nardo et al. 2024, with slow walking from Schreiber & Moissenet; treadmill walking from Santuz et al. 2022, Camargo et al. 2021 and Baček et al. 2024; stairs and ramps from Camargo et al.; reaching from Garro et al. 2025 and Zhao et al. 2021; grasping from SEEDS and Hyser. Full citations and licences are on the Data page. How the cohorts were tested is on the Method page.
Also in the app
Summary and Detail
Two views of the same analysis. Summary shows only the comparisons that held up in two or more independent labs. Detail shows everything, including single-lab references, labelled “Single-lab reference, not replicated across labs”, and how each number was reached: signal and quality, features, and the processing record.
Lab workspace
Keep recordings in a local workspace: a folder of plain files, with no database and no accounts. It supports export, import, and backup, and keeps an audit log that records operator initials.
Lab cohorts
Build your own reference cohort in the workspace for a task and electrode type, from healthy adults or a population your lab defines, with written inclusion criteria. Participants are admitted one at a time and each counts once. Each refit is a new numbered version that is never rewritten, and a recording is never compared against a cohort that holds its own participant. Comparisons start at 20 participants; until then the cohort reads “Building, n = X of 20”.
Longitudinal studies
A participant’s recordings are linked across sessions in the workspace. Each session is compared with its cohort at the participant’s age on that date, and set against the session before it. A difference between sessions is reported as a change only when it exceeds the smallest change detectable in repeated recordings of the same people. Without that measure, the difference is shown but not judged.
Task selection
Walking speed picks the matching walking reference, and the movement, such as which reaching target, picks the matching reaching reference. Both are supplied at upload and recorded as supplied.
Export with preview
A de-identified study bundle is shown for review before anything is written, so you see exactly what it contains.
Corrections on the record
If a file does not say which muscle a channel is, you say so. The report records it as supplied, not read.
Declared prior filtering
If a file was already band-pass filtered, you can declare it. Processing adjusts, and the report records the declaration.
Command line
Every capability in the app is also available from the command line, for processing recordings in bulk.
Help that stays offline
A small assistant built for the app answers “where is” and “how do I” questions and points to the control in the app. It replies only with pre-written answers, so it never makes claims about the science.
Runs locally
Analysis makes no network calls. Recordings leave the machine only if your lab chooses to share them with us under a data-sharing agreement.