Rules the software will not break

A comparison is only as good as the data on both sides of it. These are the rules Parmotus follows, the evidence that its healthy references behave as they should, and the limits we know about.

Seven rules

Dead is not the same as quiet

A channel with no signal would look like a muscle doing nothing and be read as unusually low activity. Parmotus excludes it and reports its measurements missing. A quiet but live electrode is kept. The line between the two was measured on every channel of the reference datasets, more than 23,000, not assumed. The healthy references are cleaned the same way, and channels dominated by clipping or mains hum are kept out of reference builds.

Missing is missing, never zero

A measurement that could not be computed is reported as missing, with the reason. A zero in its place would be averaged in as a real value.

Withheld is not an error

When a comparison would be meaningless, because the task, the muscles, the electrode type, or the walking speed do not match a cohort, Parmotus says so and why instead of producing a confident wrong number.

Nothing is silently changed

Every transformation of the signal, including filters, corrections, and anything the user supplied, is recorded and printed in the report.

Reproducible

The same input and software version give the same output, byte for byte, apart from the report’s timestamp.

Replicated before it is summarised

A comparison reaches Summary only when two or more independent labs pass the between-lab test below. Everything else appears in Detail, labelled single-lab.

Limitations written down

Every limitation we find is written down. The current ones are listed below.

4% apart 98% 2% one stride not 94% apart

Timing measured on a circle

A stride has no edge. A muscle peaking at 2% of the stride and one peaking at 98% are 4% apart, not 94%. Parmotus compares timing on a circle, and treats muscles with two bursts per stride, like the erector spinae, as two bursts.

How the references were tested

The expected share of healthy people outside the range is not 5%: it depends on cohort size, about 13% at 20 people and 6.8% at 100. For overground walking, each person is left out in turn across the five pooled labs. The median outside rate over 355 measurements is shown below; the mean is 6.3%.

Then each of the five labs is held out in turn and compared against a reference built without it. A measurement family holds up for a muscle when the median outside rate of its measurements is 15% or less.

6.7%
median outside rate, walking reference

A healthy range should flag only the expected share of healthy people it has never seen. Tested by leaving one person out at a time, the walking reference flags 6.7% on the median measurement, against 6.8% for a perfectly calibrated range.

Outside rate for each of 355 walking measurements, healthy adults left out of the reference one at a time.

Tested on five labs, each left out in turn

Timing held up for 28 of 33 muscles tested, frequency 23, variability 21, amplitude 13. Summary shows only measurements that held up in at least two labs.

Measurement family Lab ALab BLab CLab DLab E
Timing 5 of 5 muscles held up 8 of 9 muscles held up 5 of 8 muscles held up 6 of 7 muscles held up 4 of 4 muscles held up
Variability 4 of 5 muscles held up 6 of 9 muscles held up 1 of 8 muscles held up 7 of 7 muscles held up 3 of 4 muscles held up
Frequency 2 of 5 muscles held up 9 of 9 muscles held up 3 of 8 muscles held up 7 of 7 muscles held up 2 of 4 muscles held up
Amplitude 0 of 5 muscles held up 5 of 9 muscles held up 5 of 8 muscles held up 3 of 7 muscles held up 0 of 4 muscles held up

Muscles that held up, of muscles tested.

Amplitude depends on amplifier gain, so Parmotus labels amplitude comparisons within-lab only.

Timing transfers best. Amplitude failed for every muscle in two labs, because amplifier gain differs between labs. Frequency often holds up but stays out of Summary: it is too close to amplitude, and labs filter differently. Coordination held up in every lab where it was measured. Asymmetry could be tested in two labs only, so it is left off the table. Summary therefore carries timing, variability, and co-contraction measurements that held up in two or more labs: 18 for overground walking.

Known limitations

  • Amplitude comparisons are within-lab only. The app says which measurement families compare across labs and which do not.
  • Gait events are harder to find in irregular or very slow walking, so timing within the stride is less certain there.
  • Slow walking, stairs, ramps, reaching, and grasping each have a reference from one lab only. Their comparisons appear in Detail, labelled as not replicated across labs.
  • The cohorts are healthy adults. Percentiles are age-adjusted for the walking, stair, ramp, and three-target reaching references, and the upper-limb references do not yet include a left-handed group.
  • Recordings with no matching cohort, such as intramuscular or needle EMG today, get no comparison.
  • A cohort describes the people and equipment it was recorded from. A result outside the healthy range means the recording differs from the cohort. Electrode placement and equipment are possible causes, not only physiology.

How recording data is handled

Runs locally. Analysis makes no network calls. Recordings leave the machine only if your lab chooses to share them with us under a data-sharing agreement.

Sharing, when a lab chooses it, has three conditions:

  1. A signed data-sharing agreement with your institution, covering de-identification, purpose, and retention.
  2. Ethics approval and participant consent that cover sharing with an outside company.
  3. A de-identified export that your lab creates and reviews in the app, which shows exactly what is included, sent through a secure upload link issued for that agreement.

What this website collects when you request access is described in the privacy policy.